TM 55-4920-328-13
Table 1-3. Leading Particulars of Test Trailer Assembly - Continued
Figure and
Index No.
Electric Start System (Cont)
Constant Current Charge Rate
Starting (lg)
7 to 17 amperes
Finishing (If)
3 to 12 amperes
Trickle
175 to 350 ma
Constant Potential Rate
Voltage (Ec)
28.5v dc
Charger Capability
35 amperes
Float Charge Voltages
0°F
28.5 1.0v dc
75°F
27.4 1.2v dc
100°F
27.0 1.0v dc
Electrolyte Level
Fully Charged
3/16 1/16 in.
(2 to 24 hr after
charging)
During Last 20 min
5/8 1/8 in.
of Charge
On Float or Trickle,
3/8 1/8 in.
(Charge Condition)
208v ac, 60 Hz,
Trickle Charger
Single-phase
Figure 1-8
Hydraulic Start System
Length (Base)
44 in.
Width (Base)
30 in.
Height (Tank)
41 in.
Pump Type
variable piston,
servo controlled
Hydraulic Fluid Tank Capacity
Hydraulic Fluid
MIL-H-83282A
Air Cleaner
oil bath
Pressure Gage Range
0 to 10,000 psig
Return Pressure Gage Range
0 to 1,000 psig
Gasoline Engine
Type
4-cylinder,
air-cooled
Fuel Required
80 octane (min)
Fuel Tank Capacity
Oil Required
Above +40°F
SAE 30
+15°
to +40°
F
SAE 20-20W
0°F to +15°F
SAE 10W
Below 0°
F
SAE 5W-20W
Crankcase Capacity
7 qt (including filter)
Battery
12-volt, lead-acid
Spark Plug Gap
0.030 in.
Valve Tappet Clearance
Intake
0.008 in
Exhaust
0.014 in.
Horsepower Rating
65.9 at 3,000 rpm
Change 2 1-73