TM 55-4920-328-13
Table 2-5. Function of Controls and Indicators --Continued
INDEX AND
REFERENCE
FIGURE NO.
NOMENCLATURE
DESIGNATION
FUNCTION OR INDICATION
ANALYZER SUB-MODULE (Figure 1-23)-Continued
7, figure
DISPLAY
Part of
Selects the display time interval (0.2 to
1-23
Control
2A1
5.0 seconds, or hold) for NIIl rpm read-
out on the POWER TURBINE speed
monitor unit (6, figure 1-23).
8, figure
FUNCTION
Part of
Selects the TEST mode or RUN mode.
1-23
Control
2A1
for self-check or operation, respectively,
of the POWER TURBINE speed monitor
unit (6, figure 1-23).
9, figure
SENSITIVITY
Part of
Used to adjust sensitivity of POWER
1-23
Control
2A1
TURBINE speed monitor unit circuitry.
10, figure
K FACTOR
Part of
Used to insert K factor correction data
1-23
Preset
2A1
into the circuitry of the POWER TUR-
BINE speed monitor unit (6, figure 1-23)
to read out speed in percent full scale.
11, figure
OIL FLOW/CONSUMP-
Part of
Used to monitor engine oil
1-23
TION Monitor Unit
2A2
consumption.
12, figure
DISPLAY
Part of
Selects the display time interval (0.2 to
1-23
Control
2A2
5.0 seconds, or hold) for display of oil
mass indication on the OIL FLOW/
CONSUMPTION monitor unit (11, fig-
ure 1-23).
13, figure
FUNCTION
Part of
Selects the TEST mode or RUN mode
1-23
Control
2A2
for self-check or operation, respectively,
of the OIL FLOW/CONSUMPTION
monitor unit (11, figure 1-23).
2-22