TM 55-2840-254-23
2-30 INSTALL STATOR VANE ASSEMBLIES (Continued)
2-30
Make certain that fifth stage stator vane
is installed with leading edge of vanes
facing forward. If vane assembly is in-
stalled wrong, the outer shroud will
protrude into airflow path. This may
cause unusual stresses on compressor
blades which could result in blade
failure.
3. Install one-half of fifth stage stator vane (12)
into compressor housing half (2).
a. Make certain that leading edge (13) of vane
faces forward
b. Install six washers (14) and six bolts (15) in
bolt hole locations (16). Finger tighten bolts
(15).
GO TO NEXT PAGE
2-241