TM 1-1500-204-23-2
Table 4-18. Operating, Proof, and Burst Test Pressure for MIL-H83797 Medium Pressure Hose
Bend
Operating
Operating
Proof
Burst
radius
temperature
Hose
pressure
pressure
pressure
Inches
(fluid or
size
(psi) (max)
(psi) 1,2
(psi) (min)
(min)
ambient)3
-3
1,000
3,000
6,000
1.75
-65 °F to +250 °F
-4
1,000
3,000
6,000
2.00
-65 °F to +250 °F
-5
1,000
3,000
6,000
2.25
-65 °F to +250 °F
-6
1,000
3,000
6,000
2.50
-65 °F to +250 °F
-8
1,000
2,500
5,000
3.50
-65 °F to +250 °F
-10
1,000
2,500
5,000
4.00
-65 °F to +250 °F
-12
1,000
2,000
4,000
4.50
-65 °F to +250 °F
-16
750
1,500
3,000
5.50
-65 °F to +250 °F
-20
500
1,300
2,000
8.00
-65 °F to +250 °F
-24
250
800
1,750
9.00
-65 °F to +250 °F
-32
200
600
1,200
12.50
-65 °F to +250 °F
1 Assemblies having aluminum flange fittings shall be pressure tested at the rated proof pressure or 1,500 psig,
whichever is less.
2
Hold proof-test pressure for not less than 30 seconds nor more than 5 minutes.
3 -54 °C to 121 °C.
NOTE
Tighten cap on hose assembly only after all trapped air has bled from line.
(5)
Immerse all hose assemblies proof tested with a gas test medium in water and observe for leakage
from hose or around fittings. Apply proof pressure for not less than 30 seconds and not more than 5 minutes.
NOTE
On hose having a braided cover, do not confuse entrapped air with leakage. Agitate hose assembly under
water to remove surface bubbles.
(6)
Reject hose assemblies showing evidence of leakage.
4-50