58. Wire Contact Removal.
WARNING
Metal tool tips are sharp and can cause injury
to personnel and/or damage to connectors.
CAUTION
Present metal tooling in some instances has
damaged the wire sealing grommet at the end
of the connectors. Plastic tools are preferred.
Caution should be exercised in the use of
tooling.
Inspect tips of metal tools for distortion or
nicks of probe before use, as connector damage
can occur.
a.
Select correct removal tool (Table 6).
Figure 14. Inserting Wire into Removal Tool
b.  Place wire of contact to be removed into
removal tool, with white tip facing connector insert
(Figure 14).