NAVAIR 01-1A-505-2
008 02
TO 00-25-255-1
Page 20
TM 1-1500-323-24-2
Table 3. MIL-C-26482 Series 1 Power and Shielded Contact Tooling
45. COAXIAL CONTACTS. When routing coaxial cable
46. CABLE AND COAXIAL CONTACT ASSEMBLY.
through connectors, coaxial contacts are superior to
To assemble coaxial contacts to applicable cable identify
other coaxial cable shield termination methods. The
cable by part number. Select proper tooling by contact
shield integrity is maintained across the contact body.
size (Table 3).
The coaxial cable groups listed (Table 2) can be
interconnected through MIL-DTL-83723 connector size
47. BACKSHELL REMOVAL AND INSTALLATION.
8 and 12 contact cavities. Match the required contact
For backshell removal and installation refer to
size to connector application and cable group. When
WP 008 03.
crimping center contact for these cables, use crimp tool
selector knob settings specified. Socket and pin contact
part numbers are listed along with corresponding color
bands. Socket coaxial contacts have a pin center contact.
Pin coaxial contacts have a socket center contact.