NAVAIR 01-1A-505-2
010 03
TO 00-25-255-1
Page 7
TM 1-1500-323-24-2
Figure 6. Grounding Terminator
to Figure 6 for information on the AN 3111 grounding
20. NON-ENVIRONMENTAL EMI/RFI BACKSHELLS.
termination ring.
A typical non-environmental backshell (Figure 9) is an
attachment on the back side of a connector that does
17. E M I / R F I
GROUNDING
TERMINATOR
not protect against moisture, dust and dirt but does
INSTALLATION. EMI/RFI grounding terminator
provide EMI/RFI protection. See WP 007 03 for detailed
installation procedures are contained in Figure 7.
information on non-environmental EMI/RFI
backshells:, M85049/23, M85049/24, M85049/25,
18. NON-ENVIRONMENTAL BACKSHELLS. Use
M85049/26-1 and M85049/26-2.
EMI/RFI non-environmental backshells and discard
ring.
21. ENVIRONMENTAL EMI/RFI BACKSHELLS. A
typical environmental EMI/RFI backshell (Figure 10)
19. ENVIRONMENTAL BACKSHELLS. A typical
is used when moisture entry and EMI/RFI protection
environmental backshell (Figure 8) is a device that
is needed. See WP 007 03 for information on
provides protection from moisture, dirt, air, or dust
environmental EMI/RFI backshells: M85049/6,
which may reduce performance of unit. They do not
M85049/8 and M85049/10.
provide protection from nonphysical environments
such as RF and radiation. See WP 007 03 for information
on environmental backshells: M85049/9, M85049/7,
M85049/11.