A. Cut Cable End Square and Remove Outer Jacket To 33/64
Inch
Inch Dimension. For Cable Stripping Refer To Navair 01-1A-
505-1.
Crimp Sleeve
B. Slide Crimp Sleeve Onto The Cable Out Of The Way.
C. Comb And Fold Out Outer Conductor. Strip Dielectric, And
5/6
3/8
Trim Inner Conductor To 5.164 Inch Diameter.
Inch
Inch
.
Outer Conductor
D. If Applicable, Slide Metal Cap, Small Bore First, Over
Stripped Center Conductor And Dielectric.
E. Slide Dielectric Bushing On (Large Diameter First) Until It
Butts Combed Outer Conductor.
Figure 8. Coaxial Cable and Shielded Contact Assembly (Sheet 1 of 2)