  8    9    10    11    12  13  14    15    16    17    18  
TM 1-1510-253-CL
9. Left Engine -- START
10. Engine & System Instruments -- CHECK
11. Left BLEED AIR -- CHECK HIGH then LOW
12. GPU -- Disconnect & CHECK Annunciator
13. Right GENERATOR -- RESET, CHECK then
ON
14. Left GENERATOR -- RESET, CHECK then
ON
15. BATTERY Disconnects / Current Limiters --
CHECK
* STARTING ENGINES (BATTERY)
1. AIR COND / FAN Switch -- OFF
2. Start Mode Switch -- SET As Required
3. Right PROP -- Check Unfeathered, Clear,
Cap Secure
4. Right Engine -- START
5. Engine & System Instruments -- CHECK
6. Right GENERATOR -- RESET, CHECK then
ON
7. Right BLEED AIR -- Check HIGH then LOW
8. INVERTER -- ON & CHECK (109 121
Volts)
9. AVIONICS MASTER Switch -- ON
10. START MODE Switch -- PARALLEL
11. Right GENERATOR -- CHECK Below 150
amps
12. Left PROP -- CHECK Unfeathered, Clear,
Cap Secure
13. Left Engine -- START
14. Engine & System Instruments -- CHECK
15. Left GENERATOR -- RESET, CHECK, then
ON
16. Left BLEED AIR -- Check HIGH then LOW
17. BATTERY Disconnects / Current Limiters --
CHECK