TM 1-4920-438-13&P
POWER TRAIN SHOP
REPOSITIONING ECUs
NOTE
Skip this Work Package if ECUs are not installed.
DISCONNECTING POWER FROM ECUs
1. Set MODE switch (3) on ECU (1) to OFF position.
2. Unscrew connector lock ring (7) from power input receptacle (6).
3. Pull end of connector (5) from power input receptacle (6).
4. Store cable (2) in appropriate storage location.
5. Install protective dust cap (4) on power input receptacle (6).
6. Repeat these procedures for other ECU.