TM 1-6625-476-30
2-35
2-14. TADS NSA INSTALLATION INTO SHIPPING AND STORAGE CONTAINER. (CONT)
(1) For type A base assembly, make sure clamp assembly (5) is loosened until clamp halves are
spread far enough to permit installation on NSA clamp mounting flange (3). Also, make sure
clamp halves are positioned equally on each side of locating pins (6).
(2) For type B base assembly, make sure clamp assembly (5) is loosened until clamp halves
touch bolt heads (7). Also, clamp tab must point to clamp center.
(3) Aline two locating pins (6) on base with mounting holes (8) on TADS NSA clamp mounting
flange (3).
(4) Carefully seat base on TADS NSA flange.
(5) Seat clamp assembly (5). Set torque wrench to 35 in-lb and use torque wrench to tighten
clamp assembly nut.