TM 1-6625-476-30
2-32
2-13. TADS NSA/CHANNEL BALANCE ADAPTER REMOVAL FROM NIGHTSIDE TEST BENCH.
This paragraph covers the steps required to remove the TADS NSA and channel balance adapter from
the nightside test bench, and to remove the adapter from the TADS NSA.
a. Disconnect the following cables:
P3 of cable 13083693 from P1 of TADS NSA
P4 of cable 13083693 from J2 of TADS NSA
WARNING
HEAVY OBJECT
Excessive strain can cause serious injury.
Dont: Attempt to lift or carry heavy objects alone.
Do: Get help for lifting or carrying heavy objects.
If you experience a sudden pain while lifting or discomfort after lifting, get
medical help at once.
CAUTION
DELICATE EQUIPMENT
Ensure that channel balance adapter and TADS NSA are held firmly in
place prior to unlocking handle. Exercise caution when releasing sensor
mount handle.
NOTE
Two people are required when performing this task.
b. Hold channel balance adapter and TADS NSA firmly in place.
c. Push sensor mount handle on sensor mount assembly up to unlock position and remove channel
balance adapter and TADS NSA from sensor mount assembly.
CAUTION
DELICATE EQUIPMENT
When placing TADS NSA on workbench, ensure that it is resting on its
ballast plates. Do not rest it on mirror assembly.
d. Place TADS NSA on the edge of workbench.
e. Loosen clamp assembly (1, figure 2-23). Then remove channel balance adapter (2) from
TADS NSA (3).