TM 10-4930-351-14
UNIT MAINTENANCE
ADVANCED AVIATION FORWARD AREA REFUELING SYSTEM MODEL M100A1
REPAIR BATTERY CABLE
INITIAL SET-UP:
Tools:
Materials/Parts Required:
Tool Kit, General Mechanics
REMOVAL
1.
At the accessory module, open the battery compartment cover (1) and cable storage compartment cover (2).
2.
Disconnect battery cable from battery and control box.
3.
Push battery cable through lower cut out into cable storage compartment and remove from accessory module.
DISASSEMBLY
1.
Remove tiedown straps and cable tags from battery cable.
2.
At NATO connector (3), remove the six screws (4) and washers (5) that secure the cover (6) to the connector.
3.
Loosen the two jam nuts (7) completely.
4.
Remove the two bolts (8) and lock washers (9) from the cable terminations. Remove the cables, jam nuts (7), bushings
(10) and O-rings (11) from the connector (3). Discard the lock washers (9) and O-rings (11).
5.
At the battery connector, remove two bolts (12) and flat washers (13) to separate connector (14).
6.
Remove the two nuts (15) and lock washers (16) from the cable terminations. Remove the cables. Discard the lock
washers (16).
ASSEMBLY
CAUTION
Make sure each cable is connected to the same polarity terminal in each connector ("+"
to "+" and "-" to "-"). Equipment damage may result from improper connections.
1.
At the battery connector (14), install two nuts (15) and lock washers (16) to secure the cable terminations to the
connector (14).
2.
Install two bolts (12) and flat washers (13) to secure the connector (14) halves together.
3.
At the NATO connector (3), slide the jam nuts (7), bushings (10) and O-rings (11) onto the cables and insert the cables
into the connector (3).
4.
Install the two bolts (8) and lock washers (9) to secure cables to connector (3) and tighten jam nuts (7). Observe proper
polarity. Ensure cable connected to "-" terminal of battery connector is connected to "-" terminal of NATO connector.
0051 00-1