TM 10-4930-351-14
0093 00
2
7
6
1
5
4
3
INSTALLATION
1.
Lightly lubricate O-ring (6) with petrolatum and install in inlet O-ring groove. Do not allow the O-ring (6) to twist or
roll during installation.
2.
Install inlet (1) in pump.
a.
Install the inlet (1) by aligning the six retaining screw holes and the jack bolt holes with corresponding holes in the
pump housing (2). Tap inlet (1) lightly around circumference with rubber mallet or heel of palm to seat inlet (1) in
housing. If inlet (1) does not install easily, install the 1/4-28 x 1-1/2" jack bolts in the inlet and adjust bolts until
inlet (1) is parallel to impeller housing, then back out jack bolts alternately 1/2 turn at a time until mounting screws
(3) can be started.
b.
Lubricate with anti-seize compound and loosely install the six socket head screws (3), lock washers (4) and flat
washers (5) in the inlet (1). Tighten in a crossing pattern, one or two turns at a time, to fully seat the inlet (1) in the
pump housing (2). When all six screws are snug, tighten alternately until secure. Rotate shaft by hand to check for
freedom of rotation. Some slight rubbing at the inlet (1) is normal but if the shaft binds or will not turn, adjust
tightness of inlet mounting screw (3) until shaft turns freely.
END OF WORK PACKAGE
0093 00-2