TM 10-4930-351-14
0094 00
REMOVAL - Continued
NOTE
The stationary seal portion of the rotating shaft seal will remain in the shaft seal housing
and must be pushed out.
10. Remove the stationary seal portion (11) of the rotating shaft seal (12) from the shaft seal housing (4). Discard the seal
(11).
NOTE
Note installation direction of rotating spring portion of shaft seal for reassembly.
11. Remove spring (13) and spacer (14) as a unit.
12. Press spring (13) off spacer (14) and discard spring (13).
13. Remove and discard shaft O-ring (15). Do not remove other shaft components (thrust washer [16], dowel [17] and shims
[18]) unless replacement is necessary.
14. Remove and discard the shaft seal housing O-ring (19).
15. Inspect and clean O-ring grooves as required. Any debris or foreign material may prevent the O-rings from seating
properly.
20
19
17
16
12
10
18
9
15
14
13
11
4
8
7
6
3
5
2
1
0094 00-2