TM 55-2840-254-23
4-4 REPAIR THERMOCOUPLE JUMPER LEAD (Continued)
4-4
When using compressed air for cleaning,
use approved protective equipment for
eyes and face. Do not use more than 30
psig air pressure. Do not direct air tow--
ard yourself or another person. Failure
to comply could result in injury to eyes
or skin. In case of injury, get medical
attention.
3. Wear goggles. Remove loosened particles from
connector (2) using clean, dry compressed air.
INSPECT
FOLLOW-ON MAINTENANCE:
None
END OF TASK
4-15