INSTALL THIRD TURBINE NOZZLE AND SUPPORT (AVIM) (Continued)
4-32
5. Apply anti-seize compound (E5) to 23 bolts
(13). Align matchmarks (8 and 12) and bolt
holes. Install third turbine nozzle and support
(5) and 23 bolts (13)
on power turbine assembly
(9). Do not install bolts (13) into five bolt holes
(14) on left sides of thermocouple tubes.