TM 55-2840-254-23
4-32 INSTALL THIRD TURBINE NOZZLE AND SUPPORT (AVIM) (Continued)
4-32
e. Place locating bar (T1) (18) on fourth stage
turbine nozzle outer flange (22).
f. Measure from top of locating bar (T1) (18) to
leading edge of highest blade root. Use
micrometer depth gage Record as
Dimension D.
GO TO NEXT PAGE
4-148.2