TM 55284025423
Change 6 4169
426 INSTALL FOURTH STAGE POWER TURBINE ROTOR (AVIM) (Continued)
426
6.
Using induction heater (T50) (14) and control
unit (T55) (15), heat fourth stage power tur-
bine rotor (4) for no more than ten minutes
maximum.
NOTE
Dry ice may be used to cool turbine shaft to
facilitate installing the turbine rotor.
GO TO NEXT PAGE