TM 55-4920-328-13
SECTION XV. T700 METS TEST ADAPTER MAINTENANCE
6-57. Scope.
Maintenance of the T700 METS test adapter
involves the following periodic and routine preventive
maintenance procedures:
·
General inspection, cleaning, reconditioning, and
parts replacement in accordance with Sections I
through VII (as applicable) and paragraph 6-58.
·
Routine preventive maintenance of various specific
components in accordance with table 6-6. The table
specifies the requirements and intervals for these
procedures. Step-by-step instructions necessary in
maintenance procedures for the major component
subassemblies are given in paragraphs below and
are referenced in the table.
Table 6-6. Inspection and Maintenance Requirements for T700 METS Test Adapter
REFERENCE
COMPONENT
INSPECT FOR
INTERVAL
PARAGRAPH
Water Brake and
a. Obvious damage
Before each use
6-58
Torque Element
b. Excessive bearing
50 hours of
6-59
clearance
operation
c. Depot maintenance
150 hours of
operation
Inlet Duct and
Breaks in screen, lock-
Before each use
6-58
Screen
wire, welds, thermo-
couples, harnesses and
connector pins, and
deformation of parts
PAS and LDS
Obvious damage, security
Before each use
6-58
Control Cable
of attachment and sprockets,
and
Assembly
and proper chain tension
6-60
Variable Stator
Obvious damage, security
Before each use
6-58
Transmitter
of attachment and lockwir-
ing, straightness of shaft,
and evidence of cracks in
bellows
Lube Water Filter
a. Obvious damage, leaks,
Before each use
6-58
System
and proper operation of
and
pressure switches
6-61
b. Clean filter elements
5 hours of
6-61
operation
c. Filter element
50 hours of
6-61
replacement
operation
Change 2 6-42