TM 1-1500-323-24-2
Table 5. MIL-DTL-22992 Class L Connector Current Rating Insert Arrangements
Table 6. MIL-DTL-22992 Class L Electrical Distribution Application
grommet holes, build up wire outside diameter by
52. TOOLS AND MIL-DTL-22992 CONNECTOR
applying heat-shrinkable insulating sleeving. This
MAINTENANCE.
must be accomplished prior to contact insertion.
53. TOOLING. The procedure for attaching contacts
57. WIRE STRIPPING.
to a single conductor wire are the same for all connector
classes. Select proper tooling for specific contact part
a. Cut wire to proper length. Ensure enough wire
number (Table 7) and refer to NAVAIR 01-1A-505-1,
remains for adequate strain relief without leaving
WP 013 00 for correct assembly and crimp procedures.
excess slack.
NOTE
b. Strip insulation from end (NAVAIR 01-1A-
505-1, WP 009 00). Select contact (Table 4).
Refer to NAVAIR 01-1A-505-1, WP 011 01, for
torque value information on AS85049 connector
58. CONTACT CRIMPING.
backshells.
59. Crimp contact in accordance with following
54. BACKSHELL REMOVAL AND INSTALLATION.
procedure. Refer to NAVAIR 01-1A-505-1, WP 013 00
For backshell removal and installation refer to
for additional guidance.
NAVAIR 01-1A-505-1, WP 024 00.
a. Select crimp tool frame, positioner, locator and
55. CONNECTOR BUILD-UP.
insert bushing from the connector tooling Table 7.
56. WIRE DIAMETER BUILD-UP. If wire outside
diameter is not large enough to fill wire sealing