NAVAIR 01-1A-505-2
005 02
TO 00-25-255-1
Page 34
TM 1-1500-323-24-2
CAUTION
as close to connector as possible and attach new contact
(Paragraph 58).
Failure to remove all broken wire strands will
cause connector damage or failure to retain/
b. Starting from center of new connector,
lock contacts in place, allowing premature
maintain a smooth wire dress and insert contact into
release of contacts. If unable to ensure cavity is
correct cavity (Paragraph 55). Remove tag from wire.
clear, replace connector with a new one of the
Repeat procedure until all contacts are installed in new
same type.
connector.
h. Inspect cavity and ensure all wire segments
69. CONNECTOR BUILD-UP (SOLDER CON-
or strands have been removed.
TACTS).
68. CONNECTOR REMOVAL AND INSTALLA-
70. For buildup procedures of solder contacts refer
TION. If the connector is severely damaged and can-
to NAVAIR 01-1A-505-1, WP 016 00.
not be repaired using the above procedures, proceed
as follows:
71. CONNECTOR CLEANING AND PRESERVA-
TION.
a. Starting from outside of damaged connector,
tag wires and remove all contacts from connector
72. For connector cleaning and corrosion control
(Paragraph 64). If contact cannot be removed, cut wire
procedures refer to NAVAIR 01-1A-505-1, WP 026 00.