TM 1-1500-323-24-2
Figure 7. M39029 Contact Part Number Breakdown
42. POWER CONTACTS. Power contacts are used to
connect single conductor wire through connectors.
The power contacts range from size 10 through 22M
and are of crimp, rear release design. Contacts are
listed by size. Match the required size to connector
pin contact part numbers are listed along with
corresponding color bands (Table 2).
43. STEP STRIPPING FILTER LINE. Refer to NAVAIR
01-1A-505-1, WP 009 00.
44. THERMOCOUPLE CONTACTS. Temperature
sensing systems utilize two dissimilar metal conductors
with matched lengths. When joined at the point
temperature will be sensed, a voltage difference
develops. This voltage is directly proportional to
temperature change. Thermocouple contacts listed
Figure 8. Basic Identification Number and Color Bands
(Table 3) are either nickel-aluminum/silicon (formerly
alumel), nickel-chromium (formerly chromel), iron, or
copper-nickel alloy (formerly constantan). Match the
required size to connector application, wire gage, and
8, 12, and 16 contact cavities. Match the required contact
size to connector application and cable group. When
listed along with corresponding color bands.
crimping the center contact for these cables, use crimp
tool selector knob settings specified. Socket and pin
45. TOOLING. The procedure for attaching power and
contact part numbers are listed along with
thermocouple contacts to a single conductor wire are
corresponding color bands. Socket coaxial contacts
the same for this connector series. Select proper tooling
have a pin center contact. Pin coaxial contacts have a
for specific contact part (Table 4) and refer to NAVAIR
socket center contact (Figure 9).
01-1A-505-1, WP 013 00 for correct assembly and crimp
procedures.
47. CABLE AND COAXIAL CONTACT ASSEMBLY.
To assemble coaxial contacts to applicable cable identify
46. COAXIAL CONTACTS. When routing coaxial cable
cable by part number. Select proper tooling by contact
through connectors, coaxial contacts are superior to
size (Table 6).
other coaxial cable shield termination methods. The
shield integrity is maintained across the contact body.
48. BACKSHELL REMOVAL AND INSTALLATION.
The coaxial cable groups listed (Table 5) can be
For backshell removal and installation refer to
interconnected through MIL-DTL-83723 connector size
WP 006 04.