NAVAIR 01-1A-505-2
006 03
TO 00-25-255-1
Page 16
TM 1-1500-323-24-2
Figure 13. Inserting Sealing Plug into Contact Cavity
57. CONTACT REMOVAL. Remove wired, unwired,
and broken wire contacts in accordance with following
paragraphs.
58. Wired Contact Removal.
Figure 14. Inserting Wire into Removal Tool
WARNING
Metal tool tips are sharp and can cause injury
to personnel and/or damage to connectors.
Exercise caution when using this tooling.
CAUTION
Metal tooling may damage the wire sealing
grommet at the end of the connectors. Use of
plastic tools is preferred.
a.
Select removal tool (Table 4 or 6).
b. Inspect tips of metal tools for nicks, burrs, and
distortion of probe before use as connector damage can
occur.
c.
Place wire of contact to be removed into
removal tool, with white tip of facing connector insert
(Figure 14).
d. Slide removal tool along wire at a right angle to
connector insert face and line up with contact cavity
(Figure 15).
Figure 15. Removal Tool on Wire