i.
Pull tool straight out of contact cavity. Remove
tool from wire. Pull back lightly on wire to ensure
contact is properly seated.
j.
Seal connector as required (Paragraph 54) and
install backshell.
54. CONNECTOR SEALING.
55. Sealing Plugs. Seal connector in accordance with
following procedure:
a. Fill all unused cavities with un-crimped
contacts (Paragraph 53).
b. Insert sealing plug, large diameter first, until
bottomed in contact cavity (Figure 13). Fill all cavities
that have un-crimped contacts. Preserve connector in
accordance with NAVAIR 01-1A-505-1, WP 026 00.
56. Moisture Barrier. For connector sealing procedures,
including application of sealant to grommet sealed
connectors, refer to NAVAIR 01-1A-505-1, WP 025 00.
Figure 12. Contact Insertion