NAVAIR 01-1A-505-3
TO 1-1A-14-3
TM 1-1500-323-24-3
003 02
1 September 2011
Page 39/(40 Blank)
Figure 27. Unlocking Contact Retention
Mechanism of Broken Wire Contact
Figure 28. Broken Wire Contact Removal
54. CONNECTOR REMOVAL AND
b. Starting from center of new connector, insert
INSTALLATION. If the connector is severely damaged
contact into correct cavity (Paragraph 34). Remove tag
or cannot be repaired using the above procedures,
from wire. Repeat procedure until all contacts are
proceed as follows:
installed in new connector.
55. CONNECTOR CLEANING AND
a. Starting from outside of damaged connector, tag
wires and remove all contacts from connector (Paragraph
PRESERVATION.
38). If contact cannot be removed, cut wire as close to
56. For connector cleaning and corrosion control
connector as possible and attach new contact (Paragraphs
procedures refer to NAVAIR 01-1A-505-1, WP 026 00.
34 and 35).