NAVAIR 01-1A-505-3
TO 1-1A-14-3
TM 1-1500-323-24-3
014 03
1 September 2011
Page 6
CONNECTOR ACCESSORY BUILD-UP.
7.
8. STRAIN RELIEF INSTALLATION. Install strain relief type backshells by sliding the wiring through the
backshell prior to installing contacts in insert (Figure 5).
c. Install backshell onto connector. Observe required torque per Figures 1 thru 3.
d. Using string tie (Lacing Tape, A-A-52083 or A-A-52084) secure harness to strain relief in the indicated area in
Figure 1 thru 3 and Figure 6.
Wiring
Wiring
Harness
Harness
Connector
Strain Relief
Strain Relief
String Tie
Area
String Tie
Figure 5. Strain Relief Installation
Figure 6. Strain Relief String Tie
9.
BANDED EMI BACKSHELL. Install the banded EMI backshell as follows;
a. Insert wiring harness through backshell.
d. Install backshell onto connector. Observe required torque per Figures 1 thru 3.
e. Install banding per NA01-1A-505-1, WP 011 01 to secure harness shield to backshell in the indicated area in
Figure 1 thru 3 and Figure 7.
10. COMPRESSION NUT EMI BACKSHELL, PART NUMBERS 617925052 AND 617925054. Install the
compression nut EMI backshell as follows;
a. Insert wiring harness through backshell nut.
d. Install backshell onto connector. Observe required torque per Figure 3.
e. Install compression nut to secure harness shield to backshell in the indicated area in Figure 3 and Figure 8.
11. RACK AND PANEL SHIELD BACKSHELL. Install the rack and panel as follows;
a. Insert wiring harness through backshell.