ENGINE FIRE IN FLIGHT
L WING OVHT or R WING OVHT Light Illuminated FLASHING

Operator and Crewmember Checklist for C-26E Aircraft
Page Navigation
  34    35    36    37    38  39  40    41    42    43    44  
img
TM 1-1510-253-CL
b. GENERATOR Load -- CHECK (300
Amps Max)
NOTE
If maximum continuous power limit is not
being developed, increase power may be
obtained by selecting bleed air off.
10. TRIM -- SET As Required
11. AUTOPILOT / YAW DAMPER -- SET
As Required
12. PROP SYNCH -- SET TAKE OFF &
LANDING
13. TCAS -- Select TA Only
14. AIR COND / FAN Switch -- OFF or FAN
15. Land -- As Soon as Possible
L WING OVHT or R WING OVHT Light
Illuminated STEADY
NOTE
Intent of this procedure is to land aircraft
as soon as POSSIBLE when WING OVHT
annunciator light is observed; even if it
extinguishes and tests satisfactory.
1. BLEED AIR Switch -- OFF
2. LANDING GEAR Handle -- DOWN
3. GENERATOR Switch -- OFF
4. Land -- As Soon as Possible
If Time Permits:
5. 3 Minute Timing -- Started
6. If WING OVHT light does not extinguish
after 3 minutes:
a. LANDING GEAR Handle -- UP Only
if required for continued flight