TM 1-1510-253-CL
NOTE
Set power by matching torque to engine
with operable SRL system. If both SRL
systems are inoperative, set power IAW
the following:
NOTE
All SRL Off / Inoperative procedures
in the FLIGHT MANUAL should be re-
viewed prior to operation with SRL Off
/ Inoperative.
Manual Engine Start Will Be Necessary.
CAWI unavailable with Temp Limiter
breaker pulled.
TAKEOFF WITH SRL OFF / INOPERATIVE
1. Use actual OAT temperature and
determine EGT limit from placarded SRL
INOP EGT LIMITS chart.
2. Use OAT temperature plus 5 C and
determine target torque and performance
limitations.
3. Monitor engine closely during takeoff to
prevent exceeding EGT limits.
4. Takeoff with both Bleed Air and Engine
Deice on is prohibited with SRL Off /
Inoperative.
CLIMB / CRUISE POWER WITH SRL
OFF / INOPERATIVE
NOTE
Determine EGT limit using placarded SRL
INOP EGT LIMITS chart and appropriate
conditions.
E-12