TM 1-1510-253-CL
L SRL OFF or R SRL OFF Light
Illuminated
NOTE
Less than 80% RPM Illumination of re-
spective L SRL OFF and/or R SRL OFF
is normal. Greater than 80% RPM SRL
Switch is off or internal computer has
malfunctioned.
SRL COMPUTER FAILURE /
MALFUNCTION
NOTE
SRL System Failure may be indicated by
one or more of the following:
1. SRL OFF light illuminated above 80%
RPM
2. SRL OFF light NOT illuminated below
80% RPM
3. Sudden change in EGT of 20C or more
with no corresponding change in other
engine parameters.
4. Erratic or fluctuating EGT indication.
5. SRL- P/P power switch(es) in SRL OFF
position.
When operating with SRL computer inoperative:
6. Engine Power (Affected Engine) --
REDUCE
7. SRL- P/P power switch (Affected
Engine) -- SRL OFF
(Affected Engine - Respective ESS BUS)
9. Engine Power -- SET
E-11