TAKEOFF WITH SRL OFF / INOPERATIVE
HIGH OIL TEMPERATURE

Operator and Crewmember Checklist for C-26E Aircraft
Page Navigation
  31    32    33    34    35  36  37    38    39    40    41  
img
TM 1-1510-253-CL
L CHIP DET or R CHIP DET Light
Illuminated
(Indicates Metallic particle on Magnetic Chip Detec-
tor)
1. Prior to Takeoff -- Do not Takeoff
a. In flight, Engine Indications Normal:
-- Continue to destination & report to
maintenance.
b. In flight, Engine Indications Abnormal:
-- Execute an Engine Shutdown by
applying ENGINE FAILURE IN
FLIGHT CHECKLIST (p. E3).
BYPASS OPEN Light Illuminated
Do not test TEMP LIMITER in flight. At
high altitudes flame out may result.
NOTE
Temp Limiter opens FUEL BYPASS valve
if EGT is above 650C and RPM is above
90%.
TEMP LIMITER FAILED OPEN
1. TEMP LIMITER CB (Respective ESS
BUS) -- PULL
a. If on ground -- DO NOT TAKEOFF
b. If in flight -- Maximum altitude for
prolonged operation 15,000 feet.
TEMP LIMITER FAILED CLOSED
1. Do not advance power rapidly above
50% travel.
2. Set power levers carefully above 50%
torque to allow EGT lag.