TM 1-1510-254-CL
5. L or R FUEL PRESS annunciator
extinguished -- Check.
6. Fuel quantity -- Monitor.
ELECTRICAL SYSTEMS EMERGENCIES
DC GEN LIGHT ILLUMINATED
1. GEN switch (affected side) -- OFF,
RESET, then ON.
2. GEN switch -- OFF.
3. Operating loadmeter -- 100% maximum.
BOTH DC GEN LIGHTS ILLUMINATED
1. Both GEN switches -- OFF, RESET,
then ON.
IF EITHER GENERATOR WILL RESET:
DO NOT EXCEED 100% (88% above
31,000 feet).
3. Affected GEN -- OFF.
IF NEITHER GENERATOR WILL RESET:
4. Maintain Aircraft Control Using the
Following Instruments:
a. ESIS.
b. Pilot s PFD.
E-13