TM 1-1510-254-CL
LANDING EMERGENCIES
1. LDG GEAR CONTROL -- Check DN.
2. LANDING GEAR RELAY and LANDING
GEAR IND circuit breakers -- Check in.
3. GEAR DOWN lights -- Check
illuminated.
IF INDICATOR REMAINS UNSAFE:
4. Landing gear manual extension --
Perform.
1. Airspeed -- Below 181 KIAS.
2. LANDING GEAR RELAY circuit breaker
-- Pull.
3. LDG GEAR CONTROL -- DN.
4. Landing Gear Alternate Extension Lever
-- Unstow. Pump until three green
GEAR DOWN lights are illuminated and
gear handle red lights are extinguished.
5. Landing Gear Alternate Extension Lever
-- Stow if three green GEAR DOWN
lights illuminate and gear handle red
lights are extinguished. (Secure in
clip). Do not stow handle if three green
GEAR DOWN lights are not illuminated.
Continue pumping handle until maximum
complete leave handle at top of stroke.
Do not lower and stow handle.
GEAR-UP LANDING (ALL GEAR UP)
1. Fuel load -- Reduce.
2. Personnel emergency brieing --
Complete.
3. Loose equipment -- Stow/secure.
E-18