TM 1-1510-254-CL
18. Restrict use of Landing / Taxi Lights to
one light for 5 minutes or less.
IF AN ILS APPROACH IS REQUIRED:
19. Obtain Radar Vectors to inal, tune NAV
1, and monitor ESIS/PFD.
IF NAVIGATION USING VOR EQUIPMENT IS RE-
QUIRED:
20. Select and tune NAV 1, and monitor
ESIS/PFD.
EXCESSIVE LOADMETER INDICATION
(OVER 100%)
1. BATT switch -- OFF (monitor
loadmeter).
IF LOADMENTER STILL INDICATES ABOVE 100%:
2. Nonessential Electrical Equipment --
Off.
IF LOADMETER INDICATES 100% OR BELOW:
3. BATT switch -- ON.
1. BUS FEEDER BREAKER tripped -- Do
not reset.
2. Nonessential circuit -- Do not reset in
light.
3. Essential circuit -- Reset once. If it trips
again, do not reset.
BATTERY CHG ANNUNCIATOR
ILLUMINATED
1. Indicates battery is charging.