TM 1-1520-253-23
3.13.3.3
Access. Not applicable.
3.13.3.4
Preparation of Part. The part shall be thoroughly cleaned. Refer to Preparation of Part or Area for NDI,
3.13.3.5
3.13.3.6
Inspection Procedure. A magnetic field shall be applied to the part perpendicular to the orientation of
possible cracks. Positions for this inspection are illustrated in Figure 3-13.
a.
Select AC on the AC/DC power switch.
b.
Place probe/yoke on part in Position 1 as shown.
c.
Press the test switch and apply a light coat of magnetic particle media at the same time. Remove the
media momentarily before removing the current. Current should be applied for no more than five seconds.
d.
Inspect for cracks using the black light.
e.
f.
Rotate part-to-probe contact 90 degrees for each position and repeat steps a. through e. for Positions 2, 3,
and 4.
3.13.3.7
Marking and Recording of Inspection Results. Mark and record the inspection results as necessary per