TM 10-4930-351-14
UNIT MAINTENANCE
ADVANCED AVIATION FORWARD AREA REFUELING SYSTEM MODEL M100A1
REPLACE BATTERY
INITIAL SET-UP:
Tools:
Materials/Parts Required:
No tools required.
Compound, Corrosion Preventive
Personnel Required:
Two, any MOS
REMOVAL
1.
At accessory module, unlatch and open fully the cover (1) on the stowage chest battery compartment (2).
2.
Pull vent line (3) from battery vent tube (4).
3.
Unscrew and remove battery cable (5) from battery.
4.
Loosen wing nuts (6) on battery hold down rods (7) and push rods out of hold down ears (8).
WARNING
Serious injury could occur if heavy equipment is moved/lifted without sufficient personnel to
do the job. Always use the number of soldiers called for by the procedures to move or
relocate the AAFARS equipment. Use proper physical lifting procedures or use a suitable
lifting device or dolly. Wear safety shoes, gloves and other suitable protective clothing.
5.
Two persons lift battery from chest.
2
1
5
6
3
4
12
11
8
10
9
7
0048 00-1