TM 10-4930-351-14
0087 00
AUXILIARY PUMP
Preparation for Storage/Shipment
1.
Open unisex couplings and drain any residual fuel. Allow pump to ventilate until all trace of fuel fumes has
dissipated.
2.
With unisex couplings open, spray MIL-PRF-21260E, grade PE-10 preservative oil (WP 0116, Item 18) into pump
body. Close unisex couplings and install dust caps.
3.
Inspect electrical connector. If required, clean connectors and body interior with ethyl alcohol or equivalent, non-
conducting cleaning agent. Ensure dust cap is secured hand tight.
Preparation for Use After Storage/Shipment
Not required.
HOSES/FITTINGS/COUPLINGS/NOZZLES
Preparation for Storage/Shipment
NOTE
All nozzles, fittings and couplings of the AAFARS are made of anodized aluminum. No special preparation
for storage is required.
1.
Remove all components from reusable containers/bags.
2.
Open couplings/remove caps from kit components and drain any residual fuel. Allow component(s) to ventilate until
all trace of fuel fumes has dissipated.
3.
Repack components in reusable containers/bags.
Preparation for Use After Storage/Shipment
None required.
PRESSURE CONTROL
Preparation for Storage/Shipment
1.
Remove pressure control from container.
2.
Remove caps/plugs and drain any residual fuel. Allow pressure control to ventilate until all traces of fuel fumes
have dissipated.
3.
Repack pressure control in container.
Preparation for Use After Storage/Shipment
None required.
0087 00-5