TM 55-2840-254-23
2-8.1 ADJUST INTERSTAGE AIR-BLEED ACTUATOR (WITH WATER WASH KIT
2-8.1
PIN 2-200-071-54 INSTALLED)
INITIAL SETUP
Tools:
Powerplant Mechanics Tool Kit,
NSN 5180-00-323-4944
Technical Inspection Tool Kit,
NSN 5180-00-3235114
Compressed Air Source
Torque Wrench, 30-150 Inch-Pounds
Materials:
Carborundum Stone (E10)
Crocus cloth (E15)
Dry Cleaning Solvent (E17)
Gloves (E20)
Lockwire (E29)
VViping Rag (E58)
Tube cap MS9314-03
Personnel Requuired:
68B100 Aircraft Powerplant Repairer
68B30 Aircraft Powerplant Inspector
References:
Task 2-9
Task 2-13
Equipment Condition:
Oil Cooler Assembly Removed (Task 8-5)
General Safety Instructions:
The ignition exciter stores very high and
possibly fatal voltage. Use extreme care
when working around ignition exciter.
Serious injury could result if exciter is
accidentally grounded. Do not probe in-
side of output receptacles with fingers
or metal object. Discharge exciter only
with insulated screwdriver. In case of
shock or injury, get medical attention.
Change 5