TM 55-2840-254-23
2-8.1 ADJUST INTERSTAGE AIR-BLEED ACTUATOR (WITH WATER WASH KIT
2-81
P/N 2-200-071-54 INSTALLED) (Continued)
10.
11.
Adjust nuts (13 and 14) until clearance be-
tween shaft of pin (19) and bottom of slot (20)
is 1/8 to 3/16-inch.
Allow piston (15) to return to open position
by removing fingers from tee.
Do not allow yoke to twist when torquing nut.
Twisting of yoke may cause binding and will
not allow bleed band to close properly.
After torquing, two threads must remain
showing below nut. Failure to comply may
cause nut to break hose and prevent bleed
band from closing. Replace bleed band if two
threads do not show.
12. Position yoke (21) against compressor
housing (22) and hold upper nut (13). Torque
lower nut (14) 145 inch-pounds.
GO TO NEXT PAGE
Change 5
2-40.5