TM 55-2840-254-23
2-65 INSPECT AIR INLET HOUSING ASSEMBLY (Continued)
2-65
2. Inspect air inlet housing (1) V-band mounting
flange (2) for corrosion.
a. There shall be no more than a cumulative total
of eight inches of missing material around the
circumference of V-band clamping flange (2).
b. There shall be no individual defects (3) that
exceed 4 inches in length.
c. There shall be no individual defects (4) that
are not separated by a minimum of one inch
of unaffected material.
d. Any defects that fall within limits outlined in
preceding steps a., b., and c. shall be re-
paired. (Refer to Task 1-119).
e. Any number of random minor corroded areas
(5) not exceeding 0.025 inch diameter are
acceptable with repair. (Refer to Task 1-119).
f. A single (one) corroded area (6) is allowed
after repair provided the area does not exceed
4 inches in length and 0.070 inch in depth.
g. If limits in preceding steps a. thru e. are
exceeded, forward engine to overhaul facility.
FOLLOW-ON MAINTENANCE:
None
END OF TASK
C h a n g e
2-498.1/(2-498.2 blank)