TM 55-2840-254-23
Section XII. AIR INLET HOUSING ASSEMBLY - MAINTENANCE PROCEDURES
2-64 CLEAN AIR INLET HOUSING ASSEMBLY
2-84
INITIAL SETUP
Applicable Configurations:
All
Tools:
None
Materials:
Dry Cleaning Solvent (E17)
Gloves (E20)
Wiping Rag (E58)
Dry cleaning solvent (E17) is flammable
and toxic. It can irritate skin and cause
burns. Use only in well-ventilated area,
away from heat and open flame. In case
of contact, immediately flush skin or eyes
with water for at least 15 minutes. Get
medical attention for eyes.
NOTE
Look for accumulations of dirt conform-
ing to contour of air inlet. BuiIdup of
foreign matter maybe difficult to detect
because of the windswept contour it
assumes.
1. Wear gloves (E20). Clean visible portion of air
inlet housing assembly (1)
with wiping rag (E58)
dampened in dry cleaning solvent (E17).
FOLLOW-ON MAINTENANCE:
lnspect Air Inlet Housing Assembly (Task 2-65).
END OF TASK
2-497