TM 55-2840-254-23
2-7 INSTALL INTERSTAGE AIR-BLEED ACTUATOR (WITHOUT WATER WASH KIT
2-7
P/N 2-200-071-54 INSTALLED) (Continued)
10. Connect hose assembly (22) to union (23).
11. Connect hose assembly (24) to tee (20).
12. Connect two coil and cable assembly leads
(25) to ignition exciter output receptacles (26).
LockWire leads. Use Iockwire (E29).
13. Install screw (27) and nut (28).
INSPECT
GO TO NEXT PAGE
2-26
Change 5