2-7.1 INSTALL INTERSTAGE AIR-BLEED ACTUATOR WITH WATER WASH KIT
2-7.1
P/N 2-200-071-54 INSTALLED) (Continued)
1. Install interstage air-bleed actuator (1) over
ends of bleed band (2) and on compressor
housing (3).
2. Position bleed band (2) and intarlock bleed
band upper and (4) with tangs on piston
assembly (5).