TM 55-2840-254-23
3-8
INSTALL COMBUSTION SECTION AND POWER TURBINE (AVIM) (Continued)
3-8
(4) If clearance cannot be met, select shim
(10.1) from shim selection table to obtain
0.045 inch minimum. Use outside mi-
crometer caliper.
Example: If Dimension C is 0.035
inch, select shim Part No. 2-141-
199-01. If Dimension C is 0.025
inch select shim Part No. 2-141-
199-02. If Dimension C is 0.015
inch select Part No. 2-141-199-03.
SHIM SELECTION TABLE
PART NUMBER
SHIM THICKNESS
2-141-199-01
0.010 inch
2-141-199-02
0.020 inch
2-141-199-03
0.040 inch
GO TO NEXT PAGE
3-118.2 Change 4