INSTALL COMBUSTlON SECTlON AND POWER TURBINE (AVIM) (Continued)
3-8
(2) Measure from aft face of disc assembly
seal hub (10.3) to outer flange (10). Sub
tract thickness of locating bar (T1) (6).
Record as dimension E.
(3) Subtract dimension E from dimension D.
Result is inner axial clearance. Axial clear-
ance shall be 0.045 inch minimum. Record
as dimension F.