3-8 INSTALL COMBUSTION SECTION AND POWER TURBINE (AVIM) (Continued)
3-8
Maximum shin thickness shall not exceed
0.045 inch.
b. Calculate inner axial clearance as follows:
(1) Measure from mounting flange (7) to
nozzle rivet heads (10.2). Subtract thick-
ness of locating bar (T1) (6). Record as
dimension D.
GO TO NEXT PAGE