4-43.  Test  Equipment  Required.  The  following  test  equipment  is  required.
E Q U I P M E N
T
No.  1  Digital  Multimeter
No. 2 Digital  Multimeter
Autotransformer,  Variable
Test  Aid  (Locally  Fabricated)
SPECIFICATION
AC: 50mV to 150V, 0.5%
DC:  10mV  to  50V,  0.1%
0-150 Vac, 1500W
13 Vac to 0-6 Vac in-phase or
Frequency   Counter
Oscilloscope,  Dual  Trace 
Resistor (2 ea)
out-of-phase (See fig. 4-1)
0.5 Hz to 1 KHz, 0.1%
0 to 10 MHz
1 us to 500 ms/div
5mV  to  20V/div
2,000 ohms, 1 W, 0.1 %
4-44. Preliminary Setup.  The following must be performed prior to testing.
a. Test  the  power  supplies  and  DVM.  (Ref  para  4-40.)
b. Set the front panel controls and switches as follows:
CONTROL  OR  SWITCH
POSITION
Power  switch
OFF
SYSTEM  SELECT  switch
SAS  1
BITE  switch
-20V
EXTERNAL  METER  SELECT
VALVE
switches  (both)
SQ WAVE controls (both)
MIN
LINK  TEST  switches  (both)
VALVE
FUNCTION  SELECT  switches
CLSD  LOOP
(both)
VALVE  CONTROL  (both)
NULL
c. Connect power cable 145GS278-4 to the POWER receptacle on the test set and to the auto-
transformer.
d. Connect  the  autotransformer  to  115-volt  60  Hz  ac.  Set  the  autotransformer  for  an  output  of  115-
volts.
4-45.  Lamp  Circuit  Test.  This  test  ensures  the  lamp  test  circuit  and  indicator  lamps  function  as  re-
quired.
a. On the test set, set the power switch to ON. The POWER indicator shall come on. One lamp in
the upper or lower indicator in the SAS 1 and SAS 2 FEEDBACK SELECT, CYCLE MOTOR, and
SOLENOID  SHUTOFF  switches  shall  come  on.
4-16