TM  55-4920-428-13
NOTE
Do not adjust SAS 1 VALVE CONTROL again until specified.
Otherwise, correct test results will not be obtained. If the control is
moved, step h must be repeated.
i.  Remove  the  jumper  from  receptacle  pins  J1-3  and  J1-4.
j.  provide  an  in-phase  input  signal  to  the  SAS  1  self  demodulators  as  follows:
(1)  Fabricate  the  test  aid.  See  fig.  4-3.
(2)  Turn  the  power  switch  to  OFF.
(3)  Connect  the  primary  winding  of  the  test  aid  transformer  to  receptacle  pins  J1-1  and  J1-2.
(4)  Connect  the  in-phase  wire  from  the  test  aid  to  receptacle  pin  J1-4.
(5)  Set  No.  1  multimeter  to  measure  ac  volts.  Connect  it  to  the  test  aid  in-phase  wire  and  the  mov- 
ing  contact  of  the  variable  resistor.
(6)  Set  the  power  switch  to  ON.
Figure 4-3. Test Aid Schematic Diagram
Do not press meter X10 pushbutton switch unless the associated
nullmeter indicates less than 5 microampere. Otherwise, the
null meter can be damaged.
k.  Set  the  SAS  1  EXTERNAL  METER  SELECT  and  the  SAS  1  LINK  TEST  switches  to  SELF  FDBK.
4-18