TM    55-4920-428-13
c. Connect  power  cable  145GS278-4  to  POWER  receptacle  and  output  receptacle  of  the  auto-
transformer. Connect the autotransformer to 115-volts 60 Hz ac power source.
d. Adjust the output of the autotransformer to 115-volts ac.
e. Set  the  multimeter  to  measure  dc  volts  at  terminal  board  TB4(fig  4-1), connect  it  to  terminal
TB4-12 (+) and TB4-1.
f. Set  the  power  switch  to  ON.
g. (See fig.  4-2.)
On circuit board PS 1, adjust -V ADJ variable resistor R26 until the multi meter
indicates -12. 0-volts dc.
h. Set the power switch to OFF.
i. Disconnect the multimeter and the power cable from the autotransformer.
j. Perform  the  power  supply  and  DVM  tests.  (Ref  para  4-40.)
k. Install the panel. (Ref para 4-41.)
l. Perform the final test. (Ref para 4-42.)
4-37.   Adjustment   of   +12-Volt   Dc   Power   Supply   PS1.   (CRC)
a. Remove the panel. (Ref para 4- 18.)
b. Ensure the power switch is at OFF.
c. Connect  power  cable  145GS278-4  to  POWER  receptacle  and  output  receptacle  of  the  auto-
transformer. Connect the autotransformer to 115-volts 60 Hz ac power source.
d. Adjust the output of the autotransformer to 115-volts ac.
e. Set the multimeter to measure dc volts. At terminal board TB4 (fig.  4-1) connect  it  to  terminals
TB4-11 (+) and TB4-1.
f. Set  the  power  switch  to  ON.
g. (See fig. 4-2.) On circuit board PS1, adjust +V ADJ variable resistor R14 until the multimeter
indicates  12.0  volts  dc.
h. Set the power switch to OFF.
i. Disconnect the multimeter and the power cable from the autotransformer.
j. Perform  the  power  supply  and  DVM  tests.  (Ref  para  4-40.)
k Install the panel. (Ref para 4-41.)
l. Perform the final test. (Ref para 4-42.)
4-38.   Adjustment   of   28-Volt   Dc   Power   Supply   PS2.   (CRC)
a. Remove  the  panel.  (Ref  para  4-18.)
b. Ensure the power switch is at OFF.
c. Connect  power  cable  145GS278-4  to  the  POWER  receptacle  and  output  receptacle  of  the  auto-
transformer. Connect the autotransformer to 115-volts 60 Hz ac power source.
d. Adjust the output of the autotransformer to 115-volts ac.
e. Set  the  multimeter  to  measure  dc  volts.  On  terminal  board  TB4  (fig.  4-1), connect  it  to  terminals
TB4-10 (+) and TB4-1.
f. Set  the  power  switch  to  ON.
4-13