TM 1-1500-204-23-4
WARNING
Drycleaning solvent is flammable
and solvent vapors are toxic. Use
P-D-680, Type II Solvent in a well-
ventilated area. Keep away from
open flames. Avoid prolonged
solvent contact with skin.
(2) Cleaning. Clean turntable assembly
periodically with cloth dampened in drycleaning solvent,
Federal Specification P-D-680, Type II, and wipe dry
with a clean cloth.
(3) Operating procedures. Refer to TM 55-
4920-377-1 3&P for tester operating procedures.
(4) Safety practices. The following general
safety practices shall be observed:
·
Do not use any other electrical
power except 115 vac at 60 Hz.
Other frequencies will alter the
operation of the turntable.
·
Do not over tighten gear clutch
when making adjustments.
(5)
Maintenance.
The
following
maintenance procedures are for turntable instrument
testers:
(a) Using 1 drop of lubricating oil,
MIL-L-8383, periodically lubricate sleeve bearings.
(b) Lubricate worm and worm wheel
gear teeth with grease, MIL-G-23827.
(c) Lubricate gear shaft collar with
grease, MIL-G-23827.
d. Scorsby Base. The Scorsby base, as shown in
figure 4-5, is used as a primary test apparatus for testing
gyroscopic instruments.
(1) Inspection. Inspect the Scorsby base
using the following procedures:
(a) Inspect fan belt once a month for
wear and looseness. Replace fan belt if worn or loose.
(b)
Inspect
motor
for
smooth
operation. Replace motors that do not operate
smoothly.
WARNING
Drycleaning solvent is flammable
and solvent vapors are toxic. Use
P-D-680, Type II Solvent in a well-
ventilated area. Keep away from
open flames. Avoid prolonged
solvent contact with skin.
Figure 4-5. Scorsby Base
4-6